Drawing in. Load, system design and BOQ out.

Open your DWG or DXF. The app finds the rooms, works out the cooling and heating load for each one, sizes the system for every zone and takes off the bill of quantities, all in one workflow. You review each step.

Open your DWG or DXF. The app works through the load, the system and the take-off. You review each step.

macOS and Windows · Licence key required

Six steps. One project file.

Each step picks up what the one before it produced, so nothing is typed across from another sheet.

Open the drawing. Get the rooms.

Step 1 · Detect

Say once which layers hold walls, windows and doors. Press Detect Rooms, and every enclosed space is listed with its area for you to accept or reject.

  • Names and seat counts are read from the drawing's own labels.
  • Size filters and exclusion zones keep shafts and voids out.
  • Draw or reshape any room by hand. It snaps to the drawing, curves included.
HVAC Design Studio showing a floor plan with five named rooms coloured by zone, and the room list on the left.
A real screen from the app: five rooms detected on a sample office drawing and grouped into three zones.

Check each room before it counts.

Step 2 · Review

Select a room and its properties open beside the plan: space type, occupants, zone, schedule, ceiling height and every wall with its openings. Change what you need; the rest is already filled in.

  • Fresh air, lighting and equipment default from the space type and can be overridden per room.
  • Walls and roofs are built from real layers; the U-value is calculated for you.
  • Set a minimum airflow per room, by air changes, by area or as a fixed flow.
The Room properties panel for the Open Office: space type, occupants, zone, schedule, ventilation and loads, and the wall list.

See why, not just how much.

Step 3 · Calculate

Pick a city and press Calculate. Cooling and heating loads land in their own tabs. Then double-click a room: the Explain pane walks through its load in the order the engine works, from wall conduction to the coil.

  • A month-by-month chart shows which hour governs and why.
  • Every step names the method, equation or table it used.
  • Rooms that hit a limit, such as minimum airflow, are flagged in the table.
The Cooling Load results table with the Explain pane open on the right for the Open Office, showing the month chart and the wall conduction step with its formula.

Size the plant for the hour it really sees.

Step 4 · Size

Group rooms into zones and pick a system type for each. The Coincident peak tab adds the rooms hour by hour, and the System design tab turns that peak into equipment.

  • Per-room units, VRF air- or water-cooled, or a centralised plant, zone by zone.
  • Outdoor unit and connection ratio, constant- or variable-volume air handler, and the zone coil.
  • System outside air by the simplified or the multiple-zone method, with the critical room shown.
The System design tab for a VRF zone: the zone list with each system type and peak, the zone settings, and the outdoor unit capacity and connection ratio.

Take the quantities off the design.

Step 5 · BOQ

Press New from design on the BOQ tab. Outdoor units, indoor units and refrigerant piping are listed from the system you just sized, ready for your rates.

  • Edit any row, add sections and columns, and keep several BOQs in one project.
  • Export to Excel, or import a BOQ from any Excel layout and compare two of them.
  • VRF and per-room zones are taken off today. A centralised zone is listed as not included.
The BOQ tab with a bill built from the design: VRF works with outdoor and indoor units by capacity, then refrigerant piping, with empty rate columns.

Revision B arrives. Your work stays.

Step 6 · Revise

Point Update Floor at the new drawing. The old and new plans sit side by side, with added, removed and moved walls, doors and windows marked in colour.

  • Each changed room says exactly what differs: areas, walls, windows, occupants.
  • Re-fit, keep, edit or delete, room by room, or keep everything that did not change.
  • Space types, zones and overrides carry over. Only the geometry moves.
The Update Floor review: a list of changed rooms on the left, the current drawing and the new drawing side by side with removed windows marked in red and new walls in green.

Heating and zones, explained the same way.

The Heating Load tab: heating load and intensity for every room, with subtotals per zone and the building total.
Heating Load. Winter design conditions from the same station, steady-state envelope and fresh-air loads, a margin you set, and subtotals per zone.
The System design tab for a centralised zone: system type, air handler and outside-air method on the left, and the sized coil, airflows and outside-air results with catalogue equipment on the right.
Zone design. Choose the system type, air handler and ventilation method for a zone, and see the coil, airflows and outside air it needs beside the equipment from the catalogue.

The take-off is the slow part. So the drawing does it.

Rooms, found for you
Auto-detect finds every enclosed space on your wall layers, straight or curved. Nothing becomes a room until you accept it.
Walls and glass, by direction
Exterior walls are told apart from partitions. Every window carries its compass direction, glazing type and shading, and walls take their U-value from the layers you pick.
Cooling load, every month and hour
Each room is checked for all 12 months and 24 hours on industry-standard design weather for the station nearest your city, and the worst hour is kept.
Heating load too
Tick Heating in the load config and every room gets its winter heating load, humidification and heating airflow check from the same model, in a tab of its own.
Zones and the coincident peak
Group rooms into zones across floors. Rooms peak at different hours; the app adds them hour by hour and shows the coincident peak beside the plain sum.
A system for every zone
Choose per-room units, VRF or a centralised plant for each zone. The app sizes the outdoor unit and connection ratio, the air handler and the coil, with system outside air worked out for the whole zone.
Equipment selection
The app suggests equipment for each zone from its catalogue, working from the loads and the system type you chose.
A BOQ from the design
Outdoor units, indoor units and refrigerant piping are taken off the design for VRF and per-room zones, then edited and exported to Excel.
A calculation you can defend
Double-click any room or zone to see each step of its load. Every card shows the formula, the method it came from and the numbers that went in.
Revisions without rework
When the architect issues a new drawing, Update Floor shows what changed, room by room. The rooms you already checked stay checked.
Reports ready to hand over
Export to Excel with subtotals for each floor and zone, the Design Summary as PDF or Word, with a page for each room, and the Facade Summary of fresh air, wall and glass areas by direction.
Hours searched for every room
288
Design weather stations across India
129
Space types with built-in densities
80
Hourly schedules included
50

Built on the references your reviewers ask for.

  • Industry-standard load method

    Hour-by-hour envelope method, 129 Indian weather stations

  • Industry-standard ventilation

    Fresh air per room, and per system for centralised zones

  • ECSBC 2024

    Hourly occupancy, lighting and equipment schedules

  • SI and IP

    kW or TR, L/s or CFM, switch any time

Standards and data sources the calculation uses. HVAC Design Studio is not affiliated with or endorsed by these bodies.

The take-off, without the tape measure.

The usual way:Measure each room off the drawing and type the areas into a sheet.
With HVAC Design Studio:Rooms are detected from the wall layers, with area and perimeter worked out.
The usual way:Add up wall and glass areas for each compass direction by hand.
With HVAC Design Studio:Every wall and window carries its direction and its net area.
The usual way:Pick one design month and hour and hope it is the worst.
With HVAC Design Studio:All 288 month and hour combinations are searched for every room.
The usual way:Run the heating load as a separate sheet with its own inputs.
With HVAC Design Studio:Heating comes from the same rooms, walls and station, one tick away.
The usual way:Add up room peaks and size the plant by hand from the total.
With HVAC Design Studio:Zones are summed hour by hour, and each zone's system is sized from its coincident peak.
The usual way:Build the BOQ in another sheet, from numbers typed across.
With HVAC Design Studio:The BOQ starts from the system you sized, in the same project.
The usual way:A number in a cell that nobody can trace.
With HVAC Design Studio:Each load opens into its formula, source and inputs.
The usual way:A revised drawing means measuring again from the start.
With HVAC Design Studio:Update Floor shows only what changed and keeps the rest.
  • Multi-floor buildings Mark several floors on one sheet, and let a typical floor count as many storeys.
  • Walls and roofs from layers Eighteen materials, your thicknesses, a dark or light finish. The U-value is calculated.
  • Glazing and shading Single, double, low-e or triple glass, with overhangs and fins shading hour by hour.
  • A guide inside the app Every setting is explained in plain words, with the formula behind it.

Try it on a live project first.

One plan, priced per seat and billed yearly. Before you buy, run a pilot on your own drawing and put the load sheet beside the one you make today.

Pilot

Free

for two weeks, one seat

For a team that wants to check the numbers before deciding.

  • The full app, every feature
  • One of your own live projects
  • Help setting up your first drawing
  • Your load sheet to keep
Request a pilot

Annual licence

Per seat

billed yearly, by quotation

For engineers who size systems every week. Tell us the seats you need and the quotation arrives within a working day.

  • Cooling and heating loads, no project limit
  • Zones, coincident peak, system design and BOQ
  • Excel, Word, PDF and Facade Summary exports
  • macOS and Windows
  • Move a seat to another computer yourself
  • Activation without internet, by file
Request a quote

Questions, answered.

Which drawings can it open?

DXF files open directly. DWG files are converted first by a free DWG converter that you install once. Any drawing with walls on their own layers will work; you tell the app which layers mean what.

Which method does it use?

Cooling loads follow the industry-standard hourly method: sol-air temperatures and conduction time series for walls and roofs, solar through glass at the sun's actual angle with overhang and fin shadows, internal gains, fresh air per person and per floor area, and a psychrometric coil selection, evaluated for every hour of the design day. Heating is a steady-state winter calculation at the 99.6 % or 99 % condition. It is built for sizing at design stage. It is not an hourly energy simulation.

Does it size the equipment and produce a BOQ?

It sizes the system for each zone: the VRF outdoor unit and connection ratio, the air handler and the zone coil for a centralised plant, or the unit for each room. It suggests equipment from its catalogue and builds a BOQ from the design, which you can edit and export to Excel. VRF and per-room zones are taken off today; a centralised zone is listed in the BOQ as not included.

Does it work offline?

Yes. Every calculation runs on your own computer. The app checks its licence online from time to time, and tells you well before the next check is due. For a computer that never goes online, you can activate by exchanging a file with us.

Where is my data stored?

On your computer. A project is a single file saved next to your drawing. Your drawings and results are not uploaded anywhere; the only thing the app sends is the licence check.

How is it priced?

Per seat, billed yearly. Send us the number of seats and your billing details from the quote page and we reply with a quotation within a working day. Once it is paid, the licence keys and the invoice arrive by email.

Is there a Linux version? What about Apple silicon?

Today there are builds for Windows (64-bit) and macOS. Macs with Apple silicon run the macOS build through Rosetta 2. There is no Linux build yet.

Can I work in TR and CFM?

Yes. Switch between SI and IP at any time, or mix them unit by unit. Switching only changes how values are shown, never what is stored.

Give the take-off back to the drawing.

Runs with a licence key.

The app runs on macOS and Windows. Open this page on your computer to download it.

macOS build runs on Intel and, through Rosetta 2, on Apple silicon · Windows 64-bit. No key yet? Request a pilot.